Essential concepts about IBM Data Storage performance
The IBM DS architecture was born for mainframe use. So you need to
understand some different concepts / naming from the Debian GNU / Linux
regular ones.
The IBM DS 8300 hardware and software (it is a multi cpu Power AIX machine) is
optimized for highly parallel I/O requests.
The IBM DS 8300 hardware could be "logically partitioned" (LPAR) in
order to guarantee quality service levels (space, latency, transfer
speed) and LPARs could be grouped into Storage Facility Images (SFI) for
more availability. It is like a QoS, reserving disks, interfaces, cpus,
ram for some hosts.
The storage abstraction layers concept
The IBM DS 8300 has many
abstraction layers, progressively
grouping the
inferior layers into
higher abstraction layers,
transparently (for the Debian GNU/Linux hosts) managing availability and performance of each layer to the higher one.
Disk Drive Modules (DDM: FC or SATA) -> Array Sites (identical
DDM) -> Arrays (array sites forming "RAID" 5 or 6) -> Ranks -> 1
GB Extents -> Extent Pool -> LUN -> Virtual Logical Sub System
(LSS) -> Volume Groups -> SVC (a storage management sw).
The high performance storage, multipath, lvm and filesystem tuning overview
storage, lvm, raid and file system tuning concept diagram
Performance Connectivity
Each high transfer and rotation speed Fiber Channel DDM should be
connected by FC interfaces instead of slower SATA DDM to compose Array
Sites.
Each rank could be connected to up to 8 Fiber Channel Device Adapters (DA).
Each host computer could be connected to the SAN device through up to 8 Fiber Channel Host Bus Adapters (HBA).
If, among other ideal settings, 8 DA are connected to a server using 8
HBA, a maximum theoretical sustained write speed of 1800 MB/s could be
achieved,
given that the host multipath software is able to aggregate bandwidth instead of the regular failover behaviour.
Partial predefined configurations example
Some companies, may prefer to have some predefined configurations,
leaving less ones to the sysadmin configure when requesting storage
space.
Bellow is a real example (wich
we actually use) you should study. Please, notice that is
almost the highest performance configuration, given the connection constraints.
- 8 DDM compose 1 array site (already maximum).
- 1 array site forming 1 Array (RAID 5) (already maximum).
- 1 Array compose 1 Rank (already maximum).
- 1 Rank has many 1 GB extents.
- 8 ranks form 1 Extent Pool (already maximum).
- 1 Extent Pool compose 1 or more LUN.
- Computer hosts connect at LUN abstraction level.
- 1 Rank is connected through one Fiber Channel Device Adapter.
- Each computer host may have up to 2 FC HBAs.
- There is only 2 LPARs. One for all GNU / Linux machines and other for the mainframes.
- Sequential Prefetching Adaptative Replacement Cache (SARC)
- Adaptative Multistream Prefetching (AMP)
Volume request actual example
We used this at
our company:
- Using 15 kRPM FC DDMs, we need 8 LUNs, each from a different
Extent Pool , with extent rotation over the ranks within the Extent
Pool, with Storage Pool Striping across multiple ranks inside the Extent
Pool.
Maximum performance configuration hints
Beyond the already cited already maximum configurations at the actual
example, you may request the as many you could of the following
configurations.
- Extent rotation over the ranks within the Extent Pool.
- Storage Pool Striping across multiple ranks inside the Extent Pool.
- 15 kRPM FC DDM to form the array sites.
- 8 FC DAs for each Rank connection, if allowed.
- 8 FC HBA for each "client" connection, if allowed.
- Each LUN from different Extent Pool, if allowed.
- Variable LPAR dimensioned for your "client" application needs, if allowed.
- Connection at the Volume Group abstraction layer (on the LSS), if allowed.
- Join 2 LPARs into one Storage Facility Image (SFI), if allowed.
- 4 LUNs at one SFI (at least LPAR) and 4 LUNs at other SFI (at least LPAR), if allowed.
These configurations hints are related to the "client" host:
- Request 8 LUNs to form your host based LVM striped volume. The correct stripe width calculation is for a future article.
- Configure your host multipath for load balancing over the HBA and NEVER mount LUNs directly.
Each configuration may have severe impact on costs, notably the
LPAR, SFI related ones and the number of FC used, as they preclude other
host and apps to use allocated resources.
As of GNU / Linux 2.6.26 kernel version, multipath is still not able
to aggregate bandwidth on HBA, only implementing round robin load
balancing. So you still would not greatly benefit from having more than 2
HBAs.
Actual performance numbers for comparison
Using the already cited actual configurations, with Extent rotation
over the ranks within the Extent Pool, with Storage Pool Striping across
multiple ranks inside the Extent Pool, with15 kRPM FC DDMs to form the
array sites, and configuring Debian GNU / Linux 5.x Lenny hosts
multipath for round robin load balancing and failover, configuring 8
LUNs to form a LVM striped logical volume, using ext3 tuned for big
files, we got around 883 MB/s read and 361 MB/s write for 10 GB files.
But for heavy load hosts, the key is PARALLEL I/O, and then SAN really shines when configured and filesystem chosen and tuned.
Keep in mind that when tuned for SMALL files, the write performance
for 10 GB files suffers a significant drop. We got around 175 MB/s write
speed for ext3 tuned for SMALL files. At these conditions, common speed
tests are almost meaningless. Better benchmarking options are bonnie++
and better yet is
fio.The tests demonstrated that
tuned XFS is a much better option
for parallel I/O, but undocumented "secret" ext3 tuning tips (read the source Luke) could
almost even the numbers. Into a future article we will address these Debian
heavy parallel load LVM and filesystems "secret" tuning tips.
Resources:
IBM System Storage DS8000: Architecture and Implementation.
IBM System Storage DS8000 Information Center.
DS8000 Performance Monitoring and Tuning.
Comentários